Battery internal resistance meter tester YAOREA YR1035+. It measures the internal resistance and voltage of any type of battery or battery assembly (up to 100V) using 1kHz AC current, which meets most battery manufacturers' instructions! This device can also accurately measure the resistance of shunts.
Characteristics:
Compatible battery types:
Acid (acidic)
Li-Ion, Li-po (lithium-ion/polymer)
LiFePO4 (lithium iron phosphate)
Alkaline cell (alkaline)
Ni-MH, Ni-Cd (nickel-metal hydride and nickel-cadmium)
disk, etc.
Operating frequency: 1000Hz
Power: built-in lithium battery, 2000 mAh
Display: 2.0" diagonal; internal resistance readings: 2000 counts. Voltage data: 99999 counts. Updated 4 times per second.
Resistance measurement range:
Resistance: 20 mOhm/200 mOhm/2 Ohm/20 Ohm/200 Ohm
Maximum resolution: 0.01 mΩ/0.1 mΩ/1 mΩ/10 mΩ/0.1 Ω
Accuracy: 0.7%+7/0.5%+5/0.5%+5/0.5%+5/0.6%+5
Display mode: 22.00 mΩ (when ZR function is on)/220.0 mΩ/2.200 Ω/22.00 Ω/220.0 Ω
In the range of 5%-95% transmission, when it is not within this range (less than 5% transmission range or greater than 95% transmission range), the error may be higher than the specified accuracy.
Voltage measurement: ±(% reading +% range)
Range: 1 V/10 V/100 V
Maximum resolution: 0.00001 V/0.0001 V/0.001 V
Accuracy: 0.15+0.015/0.15+0.010/0.15+0.015
Display mode: 0.99999V/9.9999V/99.999V
Positive and negative symmetry error ±(0.012%+5 words)
Temperature drift within normal use temperature (10℃-40℃) 100ppm/℃
Maximum voltage between any terminals: 100 V. Do not exceed the specified measurement range!
Power consumption:
<60 mA (range 200 mOhm and above, backlight off at 3.7 V)
<120 mA (range 20 mOhm, backlight off at 3.7 V)
<10 mA (enter low power mode)
0 mA (disable)
Operating temperature: 10℃-40℃ Internal resistance temperature coefficient: 0.1 * (prescribed accuracy)/℃ (<18℃ or >28℃)
Only this product is discussed here. Off topic comments will be deleted! Please follow the Commenting Rules.
The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.
If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Денис - Днепр
unknown