Properties: automatic and manual change of measurement limits;
automatic shutdown;
HOLD function (holding readings on the display);
REL relative measurement function;
shockproof housing;
measurement of frequency, capacitance and temperature;
diode test and ringing of the circuit with a buzzer;
battery undervoltage indicator.
Display type: LCD indicator, 3 3/4 digits (3999)
Refresh rate: 3x/s
DC voltage measuring range: 100µ… 400m/4V/40V/400V/600V
DC voltage measurement accuracy: ±(0.5%+4 digits)
AC voltage measurement range: 1m ... 4V/40V/400V/600V
AC voltage measurement accuracy current: ±(0.8%+6 digits)
DC current measurement range: 0.1 ... 400mkA/4000mkA/40mA/400mA/10A
DC Current Measurement Accuracy: ±(1%+10 digits)
AC current measurement range: 0.1mk ... 400mk/4m/40m/400m/10A
AC Current Measurement Accuracy: ±(1.5%+10 Digits)
Active resistance measurement range: 0.1Ohm ... 400Ohm/4k/40k/400k/4M/40MOhm
Resistance measurement accuracy: ±(0.8%+4 digits)
Capacitance Measuring Range: 1p ... 4n/40n/400n/4uF/40uF/100uF
Capacitance measurement accuracy: ±(3.5%+8)
Frequency measurement range: 0.001Hz ... 1Hz/10Hz/100Hz/1k/10k/100k/1M/30MHz
Frequency measurement accuracy: ±(0.5%+10 digits)
Diode test: 0.5mA, 1.5V
Ringing the chain: acoustic signal for R
¦ <50Ω
Temperature measurement: -20 ... 1000°C
Temperature measurement accuracy: ±(1%+5 digits)
Temperature measurement resolution: 1°C
Instrument operating temperature: 0 ... 40°C
Storage temperature of the device: 0 ... 50°C
External dimensions: 145 x 74 x 36 mm
Weight with batteries: 190 g
Power supply: 2 batteries 1.5V (AAA)
Accessories: set of test leads; type K thermocouple probe ("drop" with open junction).