·Small volume, low weight, high efficiency
·Protections, short circuit/over load/over voltage
·cooling by free air convectio
·can be installed on DIN rail: TS-35/7.5or TS-35/15
·LED indicator for power on
·100% full load burn-in test
·2 Year warranty
Model
|
DR-60-5
|
DR-60-12
|
DR-60-24
|
output
|
DC voltage
|
5V
|
12V
|
24V
|
Voltage tolerance
|
±2%
|
±1%
|
±1%
|
Rated current
|
6.5A
|
4.5A
|
2.5A
|
Current range
|
0~6.5A
|
0~3.5A
|
0~2.5A
|
Rated power
|
32.5W
|
54W
|
60W
|
Ripple&noise
|
100mvp-p
|
100mvp-p
|
150mvp-p
|
DCvoltage ADJ.range
|
±10%
|
±10%
|
±10%
|
input
|
Voltage range
|
90~264VAC, 127~373VDC
|
frequency
|
47~63HZ
|
AC current
|
1.2A/110VAC, 0.65A/220VAC
|
efficiency
|
76%
|
82%
|
84%
|
Inrush current
|
Cold start current 25A/115VAC, 50A/230VAC
|
Leakage current
|
< 1mA/240VAC
|
protection
|
Over load
|
Rated output power105%~150% start over load protection
|
protection type?hiccup mode?auto-recovery after fault condition is removed
|
over voltage
|
6.8~8.2V
|
15.6~17.8V
|
30.6~33.2V
|
protection type:cut off output voltage,diode clamp
|
environment
|
Working temp,humidity
|
-20°~+60°C 20% ~ 90% RH
|
Storagetemp,humidity
|
-40°~+85°C 10% ~ 95% RH non-condensing
|
Withstand vibration
|
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes
|
safety
|
Withstand voltage
|
I/P-O/P, 3KVAC I/P-FG, 1.5KVAC O/P-FG, 0.5KVAC
|
Isolated resistance
|
I/P-O/P,I/P-FG,O/P-FG, 100M ohms/500VDC
|
standard
|
Safety standard
|
UL1012
|
EMC standard
|
EN55022?CLASSA
|
others
|
Dimension
|
78*93*56mm (L*W*H)
|
Weight
|
0.32kg
|