• Number of channels: 2
• Bandwidth : 50 MHz
• Input impedance 1 MOhm
• Input capacitance 25 pF
• Sampling rate: 150 MHz (150 megasamples per second)
• Vertical resolution 8 bits
• Memory buffer 10-64 kilobytes per channel
• Freely adjustable pre-trigger/post-trigger mode: 0% ~ 100%
• Recorder mode, mask testing
• Sweep modes: auto, normal, single
• Triggering on channel 1, on channel 2, external trigger
• Cursor measurements
• 23 automatic measurement parameters (see below)
• Fourier spectrum analyzer, 4 types of math operations(see below), Lissajous
• Automatic setting of optimal timebase and triggering
• Aluminum housing
• USBXI interface TM interface*, USB2.0, no additional power required,
* Several such oscilloscopes can be connected to one computer to create combined instruments
• Data saving, formats: BMP, JPG, Excel; saving of instrument settings
• Software for Windows NT/2000/XP/Vista/7
• Labview driver included
• Dimensions : 200x120x35 (mm)
COMPUTER REQUIREMENTS:
Minimum configuration:
-
Operating system: Windows XP/Vista/7.
-
Processor with a clock speed of 1.00 GHz or higher .
-
Memory 128 megabytes or more.
-
Disk space 500 megabytes.
-
Display with 800x600 resolution.
Recommended configuration:
-
Operating system: Windows XP SP2/
-
Processor with a clock speed of 2.4 GHz or higher.
-
Memory 512 megabytes or more.
-
Disk space 80 GB.
-
Display with a resolution of 1024 x 768 or 1280 x 1024 at normal size of 96 dots per inch.
Math functions:
- signal A + signal B
- signal A — signal B
- signal A x signal B
- signal A / signal B
- fast Fourier transform
Automatic measurements:
- amplitude of the fundamental frequency
- total harmonic amplitude
- noise level
- signal-to-noise ratio
- effective number of bits (the number of ADC/DAC bits needed to give the same signal-to-noise ratio)
- signal-to-noise ratio (but here noise also includes harmonics)
- harmonic distortion factor
- RMS value of the measured signal
- RMS value of the fundamental frequency
- RMS value of harmonics and noise
- maximum voltage
- minimum voltage
- peak-to-peak amplitude
- top voltage of the statistical maximum (excluding overshoots)
- base voltage of the statistical minimum
- middle 50% from top to base
- RMS value of the entire measurement
- amplitude base — top
- arithmetic mean of the entire measurement
- arithmetic mean of the first cycle
- positive overshoot (max-top *100%)
- negative overshoot
- period duration
- frequency
- rising edge
- fall
- duty cycle for logic 1 and logic 0, in percent
- duration of logic 1 and logic 0