1) Charge level «Low» voltage 13.8 V
Used for charging and maintaining all battery types (including AGM and gel), and also when the charger operates in 12V power supply mode. The current is set to the maximum value with the regulator on the front panel. At 13.8V, the battery can remain connected to the charger indefinitely.
2) Charge level «Medium» voltage 14.4V Main charge level for all battery types, incl., gel and AGM. The current is set from 0.05 to 0.2 C, where C is the battery capacity in ampere-hours. Charging time 10-12 hours (at 0.1C).
3) Charge level «High» voltage 16.2 V
Used ONLY FOR SERVICEABLE BATTERIES and ONLY WITH THE BATTERY REMOVED FROM THE VEHICLE, when other levels «do not charge». For example, for deeply discharged batteries, for charging at low temperatures (below -5°C), for charging alkaline batteries.
To recover lead-acid batteries, the current is set to 0.05C; the charging time during recovery is 10-12 hours.
For charging at low temperatures current is set to 0.1-0.2C, charging time 2 hours. Attention!!! Always make sure there is no ice in the battery to avoid a battery explosion.
For alkaline batteries the current is 0.1-0.2C, charging time 10-20 hours.
Only registered users can leave feedback and ask questions
The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.
If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Ярослав
unknown