- automatic shutdown;
- large LCD display (28 mm) with backlight;
- PEAK HOLD function (storage of peak values);
- elastic protective cover ("galosh");
- measurement of frequency, capacitance and temperature;
- measurement of hFE transistors using the supplied adapter;
- manual change of ranges;
- extended measurement range of active resistance 2000MOhm;
- diode test and ringing of the circuit with a buzzer;
- low battery indicator.
Display type: LCD 3 1/2 digits, height 28mm
DC voltage measuring range: 0.1m ... 200m/2V/20V/200V/1000V
DC voltage measurement accuracy: ±(0.5%+3 digits)
AC voltage measuring range: 0.1m ... 200m/2V/20V/200V/750V
AC voltage measurement accuracy: ±(0.8%+5 digits)
Frequency bandwidth for measuring AC voltage: 40Hz ... 400Hz (up to 200V), 40Hz ... 100Hz (up to 750V)
DC current measurement range: 1mk ... 2m/20m/200m/20A
DC Current Measurement Accuracy: ±(0.8%+3 digits)
AC current measurement range: 1mk ... 2m/20m/200m/20A
AC Current Measurement Accuracy ±(1%+5 Digits)
AC current measurement bandwidth: 40Hz ... 200Hz
Active resistance measurement range: 0.1Ohm ... 200Ohm/2k/20k/200k/2M/20M/2000MOhm
Resistance measurement accuracy: ±(0.8%+3 digits)
Capacitance measurement range: 10p ... 20n/2000n/2mk/20mk/200mkF
Capacitance measurement accuracy: ±(2.5% +20)
Frequency measurement range: 1Hz ... 2k/20k/200k/2M/10MHz
Frequency measurement accuracy: ±(0.5%+4 digits)
Temperature measurement: -40 ... 1000°C
Temperature measurement accuracy: ±(1%+4 digits)
Inductance measurement: 1mk ... 2m/20m/200m/2G/20G
Inductance measurement accuracy: ±(2.5%+20 digits)
Checking hFE transistors: 3V
Diode test: 1mA, 3V
Ringing the chain: acoustic signal for R
¦ <70Ω
External dimensions (hxwxd): 189 x 97 x 35 mm
Weight with batteries: 400 g
Power supply: 1 pc battery 9V 6F22 ("Krona")
Accessories included:
adapter for measuring capacitance and hFE transistors;
set of measuring wires;
ball probe type K finished with "banana" plugs 4mm TP-09;
Optional equipment:
soft case AX-58P.