The XH-W1315 high-temperature digital thermostat module with a K-type thermocouple controls heating or cooling in various devices. Thanks to its wide measurement range from -30°C to +999°C and simple controls, it can be used, among other things, to build and repair soldering stations.
Specifications:
-
Temperature range from -30°C to +999°C
-
Temperature accuracy - ±1°C
-
Temperature sensor - K-type thermocouple
-
Sensor calibration offset range - from -10°C to +10°C
-
Hysteresis range - from 1°C to 100°C
-
Supply voltage - 12V
-
Power consumption - <3W
-
One relay output
-
Switching load - 250V 10A
-
Display type - LED, combined
-
Display size - 38x20mm
-
Size module - 79x51x27mm
-
Weight - 70 g
After power-on the display shows the temperature in real time. Four buttons are used for programming: "ENT", "SET", "+", "-".
"ENT" button: short press - save the value, mute the buzzer.
"+" button: increase value.
"-" button: decrease value.
Programming modes:
P0 - operating mode: H - heating, C - cooling
P1 - hysteresis setting from 0°C to 50°C
P2 - thermocouple reading correction ±20 °C
P3 - relay and buzzer activation when the set temperature is reached. Values ON/OFF.
To set the control temperature, briefly press SET, use "+" or "- " to set the temperature, and press SET again.
To enter programming mode, hold SET for 5 seconds, then use "+" or "- " to select a menu item (P0-P3). To save settings, press and hold SET or do not press any buttons for 10 seconds. Settings are stored in the microcontroller's non-volatile memory and are kept after power-off.
In menu P2 you can calibrate the readings against a reference instrument (within ±20 °C)
To restore factory settings, press and hold "+" and "-" together for about 2 seconds; the buzzer beeps, three eights appear, the device goes to standby and starts showing the current temperature.
Heating setup example.
The boiler water must be kept at 80-90 ℃.
If the water exceeds 90 ℃, stop heating; when it cools to 80 °, start heating.
Settings are made as follows:
1. set the stop temperature to 90℃. Briefly press "SET". Use "+" and "- " to set "90".
2. set heating mode H. Press and hold "SET". Use "+" and "- " to select "P0". Briefly press "SET". Select "H ".
3. set the hysteresis to 10℃: when the water reaches +90 ℃, heating stops, and when it drops to 80 ℃, the heater turns on again. To do this, press and hold "SET". Use "+" and "- " to select "P1". Briefly press "SET" and set the value "10".
4. enable relay and alarm mode. Press and hold "SET". Use "+" and "- " to select "P3". Briefly press "SET". Select "ON ".
Cooling setup example:
The cold room must be kept at -5 ℃ ~ 0 ℃
When the temperature reaches -5℃, stop cooling; when it rises to 0 ℃, start cooling again.
Settings are made as follows:
1. set the stop temperature to -5℃;
2. set the operating mode to cooling "C";
3. set the hysteresis to 5℃: when the temperature reaches -5℃ cooling stops, and when it reaches 0℃ cooling starts again.
4. enable relay and alarm mode. Press and hold "SET". Use "+" and "- " to select "P3". Briefly press "SET". Select "ON ".