Whole catalog Measuring instrumentsMultimeters, current clamps and accessories for themDigital multimeters
 Measuring instrumentsMetal detectors, detectors of hidden wiring
 Measuring instrumentsCable testers, locators
Код товара:
039930

Multimeter MESTEK DM100C, true RMS

Digital multimeter with high measurement speed, with True RMS, VFC, NCV, LIVE functions
Multimeter MESTEK DM100C, true RMS
1 331,00 UAH × = 1 331,00 UAH
from 1 pc : 1 331,00 UAH
from 3 pcs : 1 198,00 UAH ( -10,0%)
from 6 pcs : 1 065,00 UAH ( -20,0%)

Current balances:

Магазин-Днепр
3 pcs
For Online Orders
32 pcs

Изображение товара

Product description format_size zoom_out zoom_in

MultimeterMESTEK DM100Cbased on the popular DTM0660L chip (HYCON HY12P65 clone) with a high measurement speed (10 measurements per second) has 10,000 counts, analog and double digital scales. Designed to measure AC and DC current and voltage, resistance, capacitance, there is a “continuity” and diode test, NVC non-contact voltage detector and phase wire detection mode, indication of blown fuses and protection from “fool”. Note the additional function of the V.F.C. filter. (variable frequency converter - low-pass filter), which is convenient when measuring pulsed sources with high-frequency parasitic ripple.

MESTEK DM100CPowered by two AA cells and has an automatic power off function after 15 minutes of inactivity. The function can be temporarily disabled by turning on the power supply while holding down the "SEL" button. The device uses manual selection of the measurement limits using a rotary switch.

Multimeter Application:

  • measurement of voltage and strength of direct and alternating current;
  • measurement of electrical capacitance and resistance; -
  • measurement of current frequency and duty cycle;
  • measurement of ambient temperature and humidity;
  • continuity monitoring and diode testing;
  • automatic/manual selection of measurement ranges;
  • fixing the maximum and minimum measurement values.

Features of the:

High measurement speed
Fast dual-core CPU
Function "Foolproof" - the device can, for example, be accidentally turned on to 220 volts in any mode (except for measuring current) and it will not burn out
The RM406A measures ac voltage and ac current with True Rms and has a resolution of 10,000 samples.
The device is equipped with an inverse LCD display with a semicircular pseudo-analogue scale. 1000 thousand counts per measured value range
The VFC (voltage frequency converter) function is a filter that allows you to correctly measure the voltage at the output of frequency converters.
Measuring AC current and voltage using the True RMS method, the device shows the correct values ​​when measuring AC voltage and current of any shape, not just sinusoidal. Declared frequency range - up to 1 kHz
Fast intelligent “dialing” and checking of PN junctions of semiconductor devices. The processor of the device determines the mode: whether you are checking the continuity of the circuit or diodes
LED flashlight that can be quickly turned on by pressing a dedicated button
Measuring frequency simultaneously with measuring AC voltage or AC current. The instrument always displays the frequency when measuring these quantities. Frequency measurement up to 10 MHz
Audible signaling of blown fuse in the current measuring circuit. If the fuse burns out in the device, it will let you know about it with loud intermittent sound signals.
Fast method for measuring large capacities (electrolytic capacitors). There is no need to wait long when measuring large capacities of the order of thousands and tens of thousands of microfarads. The device measures capacitances up to 100'000 uF
Sound signaling of incorrect inclusion of probes. If the selected measurement mode does not match the way you connected the probes to the sockets, the device will sound warning signals. For example, if the measurement limit is 10 Amperes, and the probe is connected to the socket for measuring low currents.
Very fast resistance measurement even at low resistances.
Non-contact voltage sensor - allows you to remotely determine the presence of live wires, for example, hidden wiring
Battery and battery check mode. The device has 2 battery test modes: 1.5V and 9V. In 1.5V mode, the battery load current is 40 mA and in 9V mode, the battery is loaded with 20 mA
Live Line testing mode - Determination of the "Phase" wire in AC networks. Can be done in a contact or non-contact way. In this case, only one probe is used, connected to the "V" socket

Characteristics:

Mode

Range

Resolution

Error

Constant pressure

0~999.9mV/9.999V/99.99V/999.9V

0.1mV/1mV/10mV/100mV

±1.2%+3

AC voltage

0~999.9mV/9.999V/99.99V/750V

0.1mV/1mV/10mV/100mV

±1.5%+3

D.C

0~999.9mA/99.99mA/600mA/10.00A

0.1mA/0.01mA/0.1mA/10mA

±1.0%+3

Alternating current

0~99.99mA/600mA/10.00A

0.01mA/0.1mA/10mA

±1.0%+3

Resistance

0~999.9Ω

0.1Ω

±0.8%+3

 

0~9.999KΩ/99.99KΩ/999.9KΩ

1Ω/10Ω/100Ω

±0.8%+3

 

0~9.999MΩ/99.99MΩ

1KΩ/10KΩ

±1.2%+5

Capacity

0~9.999nF/99.99nF/999.9nF

0.001nF/0.01nF/0.1nF

±4.0%+5

  0~9.999μF/99.99μF/999.9μF 1nF/10nF/100nF

±4.0%+5

  0~9.999mF 1μF

±4.0%+5

Diodes

0.15V ~ 3V Direct DC current: about 1mA; Voltage: about 3.2V

 

 

Ringing

Resistance 0 ~ 100 ohm. When the resistance is less than 15 Ohm, the built-in buzzer sounds constantly and the green indicator lights up. If the resistance is between 15 and 30 ohms, the buzzer signal is intermittent, the indicator lights up green.

 

 

Temperature -20~1000°C/-4~1832°F 1°C/1°F ±1%+3 digits

Characteristics

 

 

 

Counts count

10000

 

 

Display

VA inverse display, analogue scale+double digital scale

 

 

Ambient temperature

0°C~60°C

0.1°C

±2°C

Ambient humidity

20-95%

1%

±5.0%RH

Battery test

0 ~ 1.5V (discharge current 40mA)

 

 

 

0 ~ 9V (discharge current 20mA)

 

 

Buzzer check

2KHz/2.7KHz/3V (Checking passive and active buzzers)

 

 

True RMS

1KHz

 

 

AC frequency measurement

Frequency display while measuring AC voltage

 

 

Sampling rate

Sampling rate 10 times/sec

 

 

V.F.C

Low-pass filter (Voltage-Frequency converter). Actual value 40 Hz - 400 Hz (VFC: 2 kHz, damping, 3dB)

 

 

Blown fuse alarm

Fuse blown alarm 600mA/10A: FUSE on screen with audible alarm

 

 

Wrong connection alarm

Wrong connection alarm can prevent damage to the device due to incorrect operation mode selection

 

 

Data Freeze

Yes

 

 

Flashlight

Yes

 

 

Auto power off

Automatic shutdown in the absence of manipulation after 15 minutes

 

 

NCV

Non-contact AC voltage detection

 

 

LIVE (phase)

Phase indication when connecting one probe

 

 

Input impedance

10MΩ

 

 

Overload protection

Full overload protection for input voltage less than 250V

 

 

Low battery alarm

less than 2.4V

 



Leave your feedback or ask a question

Only this product is discussed here. Off topic comments will be deleted! Please follow the Commenting Rules.

The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.

If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Денис - Днепр unknown

Buy with this product: Посмотреть больше…