Silicone sealant
Kafuter K-5911B
One-component acid-free general-purpose RTV silicone adhesive.
Viscous, thixotropic gray paste.
K-5911 room-temperature vulcanizing silicone rubber is a dealcoholized one-component RTV silicone rubber with high viscosity, good thixotropy, and neutral, non-corrosive properties. This room-temperature vulcanizing silicone rubber features high heat resistance, high pressure resistance, solvent resistance, low shrinkage and no degradation.
Suitable for bonding and sealing large gaps (0~6 mm); it is waterproof, oil-resistant, impact-resistant and vibration-resistant.
Recommended use:
1. For sealing terminals on both sides of the heating tube, as well as for bonding magnetic tiles and housings of small motors.
2. For sealing, fixing and shock protection of electronic components such as high-voltage units, intermediate circuits, electrical plugs, rectifier tubes, and protection of capacitor connections.
3. Bonding and sealing of high-voltage components, sensors, transformers and high-voltage terminals.
4. Widely used for bonding metals, glass, ceramics, semiconductor devices, plastics and other objects.
5. For sealing high-temperature furnaces, steam irons and industrial high-temperature pipelines.
Packaging: 100 gram tube.
Specifications:
|
Before curing
|
Parameter:
|
Test value:
|
|
color
|
black
|
|
Viscosity (cP)
|
medium
|
|
Density (g/cm³)
|
1.2~1.3
|
|
Surface drying time (25℃, min)
|
5-10
|
|
After curing
|
Mechanical properties
|
Tensile strength (MPa)
|
1.5
|
|
Elongation at break (%)
|
200
|
|
Shear strength (MPa)
|
1.5
|
|
Hardness (Shore A)
|
50
|
|
Withstand pressure (MPa)
|
10
|
|
Operating temperature range (°C)
|
-60~260
|
|
Electrical properties
|
Dielectric strength (kV/mm)
|
20
|
|
Dielectric constant (at 60 Hz)
|
2.8
|
|
Volume resistivity (Ohm*cm)
|
2×10¹³
|
Usage recommendations:
One-component silicone compounds cure by reacting with moisture in the air. They cure well at room temperature at a relative humidity of 30% to 80%. About 90% of their physical property values are reached within 24 to 72 hours. Curing can be accelerated by gentle heating, no higher than 60 °C.
Silicone sealants must be stored in sealed containers, with no contact with air.
When working with sealant, the time to apply the silicone is limited, usually from a few minutes to an hour before a surface skin forms that impairs adhesion.
One-part compound should not be used in enclosed volumes or applied in a thick layer, as curing then takes much longer.